| Our designsare based on using the latest technologies that are appropriate for the project and in compliance to relevant Indian and International codes. The designs are based on fundamental principles of energy conservation and safety. |
| |
| Care is taken that the designs protect against electric shocks, thermal effects, over current, fault current and over voltage. All these potential hazards are addressed at the time of design, resulting in an installation that is essentially free from hazards, convenient in operation and adequate for a long trouble-free service. We provide energy efficient electrical systems requiring minimum level of maintenance and providing maximum level of safety and energy saving. |
| |
| We use our knowledge to provide appropriate lighting levels for various areas in line with guidelines given by NBCC. New technologies are constantly introduced to better the standards laid down by NBCC. We are using LED lights and now Induction lights to drastically reduce power consumption per square foot. Where ever, budget permits we use sensors to switch off lighting when the space is not occupied or where natural light is available to achieve the required lux level. |
| |
| For external lighting we use, besides the conventional lighting, Solar powered lights with LEDs to reduce power consumption and give inexhaustible access to the power of the sun. For external lights that also include façade lights we provide time switches in our panels. |
| |
| that can be programmed to switch ON/OFF at designated time of the evening and morning without human intervention. |
| |
 |
|
| Electrical Power is the heart of any building, factory or any installation. Utmost care is taken to design and locate equipments that conform to local sate electricity board (SEB) rules for safety and installation. |
| |
| Metering Panels |
| H.T. Panels |
| Transformers |
| Power Control Centres |
| |
| Power Control Centres are located near the transformers to minimize voltage drops and reduce the cost of heavy cabling or bus duct. Outdoor oil type Transformers are selected on the basis of 'minimum load loss' and 'no load-loss' along with optimum loading.Where space is not available outside the building we recommend, Dry-type transformer and vacuum circuit breakers to take care of fire and safety norms. |
| |
 |
|
Stand by Generators are provided in compliance with project requirements. DG sets are backed by stand alone panels or Auto Mains Failures depending upon the critical needs of the customer. Options are available of PLC based synchronizing panels with auto load transfer and load management. DG sets conform to Central Pollution Control Board (CPCB) norms and are housed in acoustic enclosures to reduce noise pollution. |
|
| |
| Stand by Generators are provided in compliance with project requirements. DG sets are backed by stand alone panels or Auto Mains Failures depending upon the critical needs of the customer. Options are available of PLC based synchronizing panels with auto load transfer and load management. DG sets conform to Central Pollution Control Board (CPCB) norms and are housed in acoustic enclosures to reduce noise pollution. |
| |
| Exhaust gases are expelled from the work site through properly designed exhaust pipes. We take care that the stacks so designed do not create a back pressure on to the DG Set affecting its performance. |
| |
 |
|
| Each distribution Board from Substation cascading downwards to the final distribution boards are designed to suit the needs of each level which have discriminative Fault currents and hence the circuit breakers are differently designed for each level. |
| |
| We are committed to reduce the costs of the distribution system based on the fault levels that are carefully calculated and incorporated in our designs. |
|
|
| |
| Final distribution boards incorporate safety devices like ELCB’s and surge protectors along with MCB’s. Identification tags are assigned to each level from PCC down to each outgoing circuit of the Final Distribution Boards catering to lights, small power circuits and UPS circuits. |
| |
| At Rotopower we undertake designs of Low Voltage systems for all our installations |
| |
 |
|
| Our designs for Voice and Data Networking systems are based upon integrating the five areas. |
| Work stations comprising of I/O |
| Horizontal system comprising of Cat-6e wiring and raceways |
| Vertical comprising of Patch Panels or Jack Panels |
|
|
| We keep ourselves abreast of latest technology in cabling systems and adapt the same to give best solutions to our clients. |
| |
 |
| Based upon the latest technology and project specific requirement, our MATV systems are designed to minimise signal losses and ensure excellent audio/video quality. We provide complete solutions for hotels and buildings. |
| |
 |
| We design and deploy stand alone UPS and inverters or deploy UPS in parallel redundant mode depending upon the criticality of the operation for computers, servers, data centers and other low voltage equipment. |
| |
 |
 |
| |
| The world is increasingly looking at methods of conserving and reducing power consumption across all installations. |
| |
| For monitoring and controlling following equipments at an optimal level of efficiency Integrated Building Management System (IBMS) is deployed. |
| |
| Building Automation System (BAS) is a micro processor control system designed to monitor and control all parameters of Building that helps in conserving energy by executing various energy efficient programs for optimized performance of the systems and to assist the operation and maintenance of the installation. |
| |
| Our BMS systems are Direct Digital Control (DDC) based with all its functions customized to suit customer requirements. The DDC interface, with sensors, actuators and environmental control systems, carry out various functions of energy management, alarm detection, time/event/holiday/temporary scheduling, communication interface/control and building maintenance & report generation. |
| |
| The systems design of the IBMS consists of the following components that can be controlled and monitored from a remote and centralized control PC: |
| |
| Chillers and AHU’s |
| Pumps and cooling towers |
| Electrical equipments like DG sets, transformers, Main LT Panels |
| Lighting DBs |
| PHE |
| Fire fighting and protection |
| Elevators and other building services/utilities |
| |
 |
|
| We design both addressable and conventional fire detection and alarm systems using UL or EN listed equipment in accordance with project and design guidelines. Main fire alarm control panel is located at a convenient location in case provision is not made for a security room. |
| |
| The Fire Alarm System is integrated with HVAC, Electrical system, Access control system, lifts and elevators: |
|
|
| |
| In case of fire it initiates following action |
- Shuts down of Air Handling Units of the affected areas
- Closing of fire dampers in AHUs
- Start the pressurization fans
- Start-up of smoke extraction fans (mechanical smoke control)
- Grounds all elevators
- Overrides access control system and opens doors
|
| |
 |
|
| Be it Public announcement system or channel music for offices and Malls, be it voice evacuation system for fire or paging we customize the Public Address System for our customers. Our systems are divided into three portions. |
| |
| Head end equipment |
| Distribution equipment |
| Reception equipment. |
|
|
| |
| The public address system comprises equipment of sufficient capacity to ensure distribution of voice to various areas of the building with equal clarity. Public address components are provided with graduated priority. The system is integrated with the Fire Alarm System through necessary interfaces. Each floor constitutes a zone with selective floor-wise isolation facility. |
| |
 |
 |
| |
| We undertake design of complete security systems which are low profile, camouflaged hardware that blends with the surroundings to give effective security protection to men and material in an installation. Be it a Mall or an Office, a factory or a warehouse we have solutions for one and all. |
| |
| Close Circuit Television system (CCTV) comprising of fixed cameras, Pan, tilt and zoom cameras located at perimeters and areas needed constant surveillance. These are backed by DVR to give live and recorded footage of events at the security room monitored through a PC. |
| |
| Intruder Alarm System comprises of motion sensors that are located at entry exit gates, glazed doors and windows, possible areas from where an intruder could break in. We design location of panic buttons and electronic hooters in case of emergencies. |
| |
| Access Control system comprises of door locks controlled by smart cards. These allow access to only authorized personnel. These access cards are also used to log in and out their presence and hence integrated with the payroll section. |
| |
| Electronic Article Surveillance system takes care of a fool proof system of protection against theft of merchandises in the Malls and shopping complexes. With installation of Reason control generator and deactivators suitable security is provided against unauthorised removable of goods from its designated area. |
| |
| |